Line, plant, product and key-equipment figures in one place, ready to print or save as PDF.
| Equipment | Prismatic ESS module & PACK assembly line |
|---|---|
| Design takt | 8 PPM (counted in cells, 1P13S reference module) |
| Reference cell | 314 Ah; designed with 587 Ah cells in mind |
| Line yield | ≥ 99 % (equipment-related defects only) |
| Stations | 21 numbered stations (incl. twin and multi-station groups) |
| Operators | About 21: cell processing 3, module 6, PACK about 12 |
| Power supply | 3-phase 5-wire 380 V ±5 %, 50 Hz, rated 250 kW |
|---|---|
| Compressed air | 0.5–0.7 MPa, flow ≥ 3000 L/min |
| Shielding gas | Nitrogen 0.5 MPa, 40 L/min |
| Floor load | ≥ 800 kg/m² |
| Footprint | 55 m × 9 m × 3.5 m (excl. warehouse & logistics aisles; adaptable to your plant) |
| H | W | L / T | |
|---|---|---|---|
| Cell 314 Ah | 207 ± 0.5 | 173 ± 0.5 | 72 ± 0.5 |
| Module | 100–240 | 150–370 | 300–1000 |
| PACK | 100–250 | 300–800 | 600–1200 |
Key equipment parameters
| Robot payload | 220 kg |
|---|---|
| Reach | ≥ 2650 mm |
| Repeatability | ± 0.06 mm |
| Cells per pick | 5 cells |
| Scan success rate | ≥ 99.9 % (excl. defective labels) |
|---|---|
| Voltage accuracy | ±(0.01 % rdg + 3 dgt) |
| IR accuracy | ±(0.5 % rdg + 10 dgt) |
| Press force | 0–8000 N |
|---|---|
| Press length | 300–1100 mm (swap press blocks by range) |
| Motion speed | 200–300 mm/s, vibration-free |
|---|---|
| Addressing accuracy | ≤ ± 0.2 mm |
| Laser power | 6 kW |
|---|---|
| Welding speed | 50–100 mm/s |
| Penetration / width | ≥ 1.0 mm / ≥ 1.5 mm |
| Pull-out force | ≥ 1000 N |
| Insulation test | DC 1000 V, ≥ 500 MΩ |
|---|---|
| Withstand test | DC 2800 V, leakage ≤ 10 mA |
| Vision accuracy | ± 0.2 mm |
|---|---|
| Path accuracy | ± 2 mm |
| Volume accuracy | 5 % |
| Load | ≥ 200 kg |
|---|---|
| Speed | ≤ 20 m/min |
| Length | Per station count |
Glossary
- PPM
- Pieces per minute; counted in cells on this line.
- OCV
- Open-circuit voltage, used to grade and sort cells.
- EOL
- End-of-line test before a unit leaves the line.
- CCS
- Cell contact system: busbars and sensing harness on one carrier.
- 1P13S
- One parallel, thirteen series: thirteen cells connected in series.
- MSD
- Manual service disconnect.
- BMS
- Battery management system.