How the calculation works
Every result is plain arithmetic on the values in a cell datasheet. S is the number of cells in series, P the number of parallel strings.
- Cells
- N = S × P
- Pack voltage
- nominal = S × cell nominal voltage; full = S × full-charge voltage; empty = S × cut-off voltage
- Pack capacity
- Ah = P × cell capacity
- Nominal energy
- kWh = nominal V × Ah ÷ 1000 = N × cell V × cell Ah ÷ 1000
- Cell mass
- kg = N × mass per cell (busbars, structure, BMS, cooling and housing come on top)
- C-rate
- current A = C × pack Ah; power kW = A × nominal V ÷ 1000; time ≈ 1 ÷ C (hours)
- Sizing from a target
- S = ⌈target V ÷ cell V⌉; P = ⌈target kWh × 1000 ÷ (S × cell V × cell Ah)⌉
- Ah and kWh
- kWh = Ah × V ÷ 1000; Ah = kWh × 1000 ÷ V
Notation: xPyS means x parallel strings of y cells in series, as on the rest of this site: 1P13S is 13 cells in series. Many cell and BMS datasheets put series first and write the same module as 13S1P.
Results use nominal values. Real capacity falls at higher C-rates, and runtime is a little shorter than 1 ÷ C because of internal losses. The current and power shown are what the cells carry at that rate, not a rating for busbars, fuses or the BMS.
Typical cell voltages
| Chemistry | Nominal | Full charge | Cut-off |
|---|---|---|---|
| LFP (lithium iron phosphate) | 3.2 V | 3.65 V | 2.5 V |
| NMC (nickel manganese cobalt) | 3.6 V | 4.2 V | 2.5 V |
| LTO (lithium titanate) | 2.4 V | 2.85 V | 1.8 V |
| Sodium-ion | 3.0 V | 4.1 V | 1.5 V |
Typical values. LFP is also quoted at 3.3 V nominal and NMC at 3.7 V; NMC is usually used above 3.0 V, with datasheet cut-offs of 2.0–2.5 V; sodium-ion limits vary by maker. Your cell’s datasheet rules.
Cell presets
| Cell | Nominal | Energy per cell | Mass per cell |
|---|---|---|---|
| LFP 314 Ah storage cell | 3.2 V | 1,004.8 Wh | 5.5–5.6 kg |
| LFP 280 Ah storage cell | 3.2 V | 896 Wh | — |
| LFP 587 Ah storage cell | 3.2 V | 1,878.4 Wh | 10–10.6 kg |
| LFP 628 Ah storage cell | 3.2 V | 2,009.6 Wh | about 11.3 kg |
| NMC 18650 cell, 3.0 Ah (typical) | 3.6 V | 10.8 Wh | 42–49 g |
| NMC 21700 cell, 5.0 Ah (typical) | 3.6 V | 18 Wh | 68–70 g |
Storage-cell masses are from our guide on moving to 500 Ah-plus cells; where it gives a range, the calculator uses the upper value. Enter your own mass for the 280 Ah cell. The 18650 and 21700 figures are typical; the calculator uses 46 g and 68 g.
Worked example: a 1P13S module of 314 Ah LFP cells
This is the reference module of the 8 PPM line on this site.
- Cells1 × 13 = 13
- Nominal voltage13 × 3.2 V = 41.6 V
- Voltage window13 × 2.5 V = 32.5 V empty to 13 × 3.65 V = 47.45 V full
- Capacity1 × 314 Ah = 314 Ah
- Nominal energy41.6 V × 314 Ah ÷ 1000 = 13.0624 kWh ≈ 13.06 kWh
- Cell mass13 × 5.5–5.6 kg = 71.5–72.8 kg (cells only)
- At 0.5 C0.5 × 314 Ah = 157 A; 157 A × 41.6 V ÷ 1000 ≈ 6.53 kW; about 2 hours
Eight such modules in series make a 1P104S pack: 104 × 3.2 V = 332.8 V, and 332.8 V × 314 Ah ÷ 1000 ≈ 104.5 kWh.
Questions people ask
01What is the difference between series and parallel?
Cells in series add their voltages; cells in parallel add their capacity (Ah). Energy grows with the number of cells either way: thirteen 3.2 V, 314 Ah cells hold about 13.06 kWh whether wired 1P13S (41.6 V, 314 Ah) or 13P1S (3.2 V, 4,082 Ah). Use series to reach the voltage your inverter or BMS needs and parallel to add capacity and current. Cells in one pack should be the same type with matching voltage and capacity; in series, the weakest cell limits the whole string.
02How do I convert Ah to kWh?
Multiply amp-hours by the nominal voltage and divide by 1,000: kWh = Ah × V ÷ 1000. A 314 Ah LFP cell at 3.2 V holds 314 × 3.2 ÷ 1000 ≈ 1.00 kWh; a 280 Ah pack at 51.2 V holds about 14.34 kWh. To go back, Ah = kWh × 1000 ÷ V. Use the nominal voltage, not the full-charge voltage.
03What does C-rate mean?
C-rate is current relative to capacity: current = C-rate × Ah. At 1C a full battery discharges in about one hour, at 0.5C in about two hours, at 2C in about 30 minutes. A 314 Ah cell at 0.5C carries 157 A. Real runtime is a little shorter than 1 ÷ C because of internal losses, and the capacity a cell delivers falls as the rate rises.
04How many cells for a 100 kWh, 51.2 V pack?
With LFP cells at 3.2 V you need 16 in series (51.2 ÷ 3.2). 100 kWh at 51.2 V is about 1,953 Ah, so with 280 Ah cells you need 7 strings in parallel: 7P16S, 112 cells, 1,960 Ah, about 100.4 kWh. With 314 Ah cells, 7P16S gives about 112.5 kWh and 6P16S about 96.46 kWh. Or raise the voltage and keep one string: 100 cells of 314 Ah in series (1P100S) make 320 V and about 100.5 kWh, with 6.25 times less current for the same power.
Sources
- Battery University, “BU-205: Types of Lithium-ion”, updated 8 December 2023: nominal voltages and operating ranges of LFP, NMC and LTO. batteryuniversity.com
- Battery University, “BU-302: Series and Parallel Battery Configurations”, updated 25 October 2021: series adds voltage, parallel adds capacity, series-first notation, matched cells. batteryuniversity.com
- Battery University, “BU-402: What Is C-rate?”, updated 25 October 2021: discharge times at 1C, 0.5C and 2C; losses at fast discharge. batteryuniversity.com
- Battery University, “BU-301a: Types of Battery Cells”, updated 24 April 2019: 18650 cells of around 3,000 mAh. batteryuniversity.com
- MIT Electric Vehicle Team, “A Guide to Understanding Battery Specifications”, December 2008: C-rate, nominal, cut-off and charge voltage; capacity falls as the C-rate rises. web.mit.edu
- J. B. Quinn et al., “Energy Density of Cylindrical Li-Ion Cells: A Comparison of Commercial 18650 to the 21700 Cells”, Journal of The Electrochemical Society 165 (2018) A3284: capacities, voltage windows and masses of commercial 18650 and 21700 cells. doi.org
- K. Bischof et al., “Evaluation of commercial 18650 and 26700 sodium-ion cells and comparison with well-established lithium-ion cells”, Journal of Power Sources Advances 27 (2024) 100148: commercial sodium-ion cells at 3.0 V nominal, 1.5–4.1 V. doi.org
- Stratavolt guide, “Moving from 314 Ah to 500 Ah-plus cells”: masses of 314, 587 and 628 Ah storage cells, with the datasheets cited there. this site
- Stratavolt line specification for the 8 PPM line, October 2026: 1P13S reference module of 314 Ah cells; module and PACK envelopes. this site
Related pages
Results are for early design estimates, not a performance guarantee for any cell or pack; base the final design on the cell datasheet and test data.