Guides

Battery pack assembly process: cell to PACK

The battery pack assembly process runs cell to module to PACK in 21 stations and three segments. Takt is 8 PPM, 7.5 seconds per cell.

Key takeaways

Route
Cell processing, then module stacking and welding, then PACK assembly and test. 21 stations, 21 operators.
Takt
8 PPM, which is 7.5 s per cell. The 1P13S reference module is 97.5 s per module.
Cell
Reference cell 314 Ah, 207 × 173 × 72 mm, with headroom to 587 Ah.
Envelopes
Module 100–240 × 150–370 × 300–1000 mm. PACK 100–250 × 300–800 × 600–1200 mm.
Plant
Footprint 55 × 9 × 3.5 m. Power 380 V 3-phase 5-wire, rated 250 kW. Floor load ≥ 800 kg/m².
Yield
Equipment-caused yield 99%.

Updated · Written by the Stratavolt applications team, checked by an engineer before publication · Editorial standards

Cells become a module, and modules become a PACK, on one line in three segments. The line has 21 stations: cell processing, module stacking and welding, then PACK assembly and test.

The interactive line view is the process page. This guide is the step list and the check at each step. Figures are from the 8 PPM engineering proposal, the same source as the rest of this site.

All 21 stations

No. Station Segment Mode
01 Full-pallet cell infeed Cell processing Manual
02 Robotic depalletizing Cell processing Auto
03 Barcode scan / OCV test Cell processing Auto
04 NG reject / OK refill Cell processing Auto
05 Cell flipping and grouping Cell processing Auto
06 Cell adhesive application Cell processing Manual
07 Module stacking and pressing (×2) Module stacking and welding Semi-auto
08 Terminal addressing Module stacking and welding Auto
09 NG rejection Module stacking and welding Auto
10 CCS / busbar placement Module stacking and welding Manual
11 Busbar laser welding Module stacking and welding Auto
12 Post-weld cleaning and inspection Module stacking and welding Manual
13 Module EOL test Module stacking and welding Auto
14 Module transfer Module stacking and welding Manual
15 Cooling-plate infeed PACK assembly and test Manual
16 Cooling-plate leak test PACK assembly and test Semi-auto
17 Lower-housing thermal adhesive dispensing PACK assembly and test Auto
18 Module boxing PACK assembly and test Manual
19 PACK assembly stations (×6) PACK assembly and test Manual
20 PACK test stations (×2) PACK assembly and test Semi-auto
21 Finished PACK offload PACK assembly and test Manual

Cell processing

A vision-guided 6-axis robot depalletizes cells, the line scans and OCV-tests them, and NG cells are rejected. Adhesive on the cell is applied by hand. The segment uses 3 operators.

The depalletizing robot is specified at a 220 kg payload, reach ≥ 2650 mm and repeatability ± 0.06 mm, and it picks 5 cells at a time. The scan and test station is specified at a scan success rate ≥ 99.9% (excluding defective labels), voltage accuracy ±(0.01% rdg + 3 dgt) and IR accuracy ±(0.5% rdg + 10 dgt).

Module stacking and welding

Twin stacking-and-press stations, vision addressing with a polarity check, 6 kW galvo laser busbar welding, then a module end-of-line test on every module. The segment uses 6 operators. Press force is 0–8000 N and press length is 300–1100 mm, with the press blocks swapped by range. Addressing accuracy is ≤ ± 0.2 mm.

After the weld, an operator cleans and inspects the joints. The module EOL tester checks insulation (DC 1000 V, ≥ 500 MΩ), withstand voltage (DC 2800 V, leakage ≤ 10 mA), total voltage and resistance, and continuity.

PACK assembly and test

A straight roller line: cooling-plate leak test, automatic thermal adhesive dispensing on the housing floor, six assembly stations, PACK end-of-line test and a full-pack leak test. The segment uses 12 operators. Dispensing vision accuracy is ± 0.2 mm, path accuracy ± 2 mm and volume accuracy 5%.

The PACK flow, in order, is: load the cooling plate; cooling-plate leak test; dispense thermal adhesive; box the modules; fix the modules; install the BMS; fit the series copper bars; fit the MSD and the high-voltage and low-voltage connectors; fit the top cover; torque the top cover; fit the front panel; PACK EOL test; full-pack leak test; PACK offload.

Test and quality gates

Gate What is checked
OCV and scan Barcode, open-circuit voltage and internal resistance; NG cells are rejected
Polarity Terminal addressing images every terminal and checks polarity
Weld 6 kW galvo busbar weld, then a manual post-weld clean and inspection
Module EOL Insulation, withstand voltage, total voltage and resistance, continuity
Cooling plate Leak test before the modules go into the housing
Adhesive Thermal structural adhesive on the housing floor, vision-corrected
PACK EOL The PACK test stations after assembly
Full pack Leak test of the finished PACK

Utilities and footprint

Item Figure
Footprint 55 × 9 × 3.5 m, excluding warehouse and logistics aisles
Power 3-phase 5-wire 380 V ±5%, 50 Hz, rated 250 kW
Compressed air 0.5–0.7 MPa, flow ≥ 3000 L/min
Nitrogen 0.5 MPa, 40 L/min
Floor load ≥ 800 kg/m²
Module envelope 100–240 × 150–370 × 300–1000 mm
PACK envelope 100–250 × 300–800 × 600–1200 mm

The same tables are on the specs page and the compatibility page.

Where people stay on this line

The line is not unattended. 21 operators run it: 3 in cell processing, 6 in module stacking and welding, and 12 in PACK assembly and test. Manual stations include cell adhesive, busbar placement, post-weld inspection, module transfer, cooling-plate infeed, module boxing, the six PACK assembly stations and finished-PACK offload. Stacking, the cooling-plate leak test and the PACK test stations are semi-automatic.

Size a layout for your building in the configurator. The full parameter tables are on specs and the cell and envelope limits are on compatibility. Buyer questions that are not the station list are on the FAQ.

Questions buyers ask

01

How long does one module take?

97.5 s for the 1P13S reference module at 8 PPM. The takt is counted in cells, one cell every 7.5 s, and the reference module is 13 cells.

02

How many stations are on the line?

21 stations in three segments. Cell processing has 3 operators, module stacking and welding has 6, and PACK assembly and test has 12.

03

What cell does the line use?

314 Ah is the reference cell, 207 × 173 × 72 mm, with headroom to 587 Ah. The module envelope is 100–240 × 150–370 × 300–1000 mm.

04

What does the busbar weld use?

A 6 kW galvo laser. The station welds at 50–100 mm/s, with penetration ≥ 1.0 mm, weld width ≥ 1.5 mm and pull-out force ≥ 1000 N.

Related pages

Prices, takt figures and parameters here are typical industry ranges for early planning and comparison; your configuration and quote come from a project proposal.

More guides

Lines, machines and key components —
one point of contact.

Beyond our own line, we run supply-chain solutions for ESS production: sorting, welding, test, logistics and MES equipment and key components, matched to your cell, capacity and budget, delivered and commissioned as one project.

WhatsApp